Designed and built for harsh power conditions, our UPS provides dependable, premium quality regulated power even under highly fluctuating input voltage and frequency (Converts the generator output into clean, computer network grade, highly regulated power supply).
TECHNICAL SPECIFICATION | |
---|---|
TECHNOLOGY | Double conversion with the latest MPWM technology using APFC 5KVA -10KVA |
MODEL | AG PFC101, Solar compatible |
RATING | 1⊘ Input - 1⊘ Output |
CAPACITY | 5KVA / 10KVA |
DC BUS | 5KVA / 6KVA / 7.5KVA / 10KVA |
INPUT | |
Input Voltage | 230VAC, 1⊘ |
Input Voltage Window | 170VAC - 270VAC |
Input Frequency | 50Hz ± 10% |
Power walk in | Soft start for 0-20 seconds power walk-in |
Input PFC | 0.99 on full load |
Input current harmonic distortion (THDI) | <7% @ 100% load |
RECTIFIER | |
Voltage Regulation | (±) 1% |
Ripple Voltage | <2% without Battery |
Battery | SMF |
Charger Type | CCCV |
Charging Current Standard | 0-10A |
INVERTER | |
Inverter Type | IGBT based MPWM with instantaneous sinewave control |
Power Factor | 0.8 lag |
Nominal Voltage | 230V/50Hz |
Regulation | (±) 1% |
Total Harmonic Linear Load | <2% |
Total Harmonic Non Linear Load | <4% |
Over Load Capacity | 125%-1 Minute : 150% 10 Seconds |
Transient Response | Output remains |
EFFICIENCY | |
Efficiency 100% load | >85-90% |
Crest Factor | 3:1 |
Mode of Operation | Designed for continuous operation |
Isolation | True online with complete galvanic isolation for comprehensive Power protection |
LCD Display shows the following parameters | Input Voltage. Output Voltage. Load percentage.Output Frequency. Battery Voltage |
Fault status display with latch | Mains on. Charger on. Inverter on. Battery low. Overload. Inverter Trip |
Protections | Advanced Electronic protection for device safety, backed up with MCB’s / MCCB’s & fast acting fuses. High speed pulse by pulse electronic device protection. Electronic over current trip with reset. Input under Voltage / Over Voltage. Rectifier over voltage. Over Temperature. Over load. Battery low. Short circuit. High voltage transient protection & ESD protection as per IEC 62040-2 |
Alarms | Input low/fail.output Overload.Over temperature.Battery low |
Enclosure Protection | IP-20 |
Cooling | Forced air |
Acoustic Noise level | <60db @ 1.5 meter |
Operating ambient Temperature | 0 to 40ºC |
Humidity | Up to 95% RH Non condensing |
Dimension in mm DxHxW wt.in Kg | 550*550*200/55Kgs Upto7.5KVA. 600*650*240/70Kgs for 10KVA |
Altitude | <3000 feet above sea level ( with out derating ) |